In Vitro Color Stability Assessment of Two Clear Aligner Types

Authors

  • Heshou Himdad Jemal College of Dentistry, Hawler Medical University, Kurdistan Region, Iraq. https://orcid.org/0009-0001-7743-9965
  • Bayan Abdulla Hassan College of Dentistry, Hawler Medical University, Kurdistan Region, Iraq.

DOI:

https://doi.org/10.15218/edj.2026.5

Keywords:

Color, Dental Materials, Elastomers, Removable Orthodontic Appliances, Polyethylene Terephthalates

Abstract

Background and Objective: Clear aligners, widely used in orthodontic treatment, are subject to various environmental stresses that can affect their performance and esthetics. In addition, due to patient non-compliance, aligners frequently contact hot beverages such as coffee and cold beverages like cola. This study evaluates the effect of these beverages, along with artificial saliva, on the color stability of clear aligner materials.

Methods: Two types of clear aligners; Polyethylene Terephthalate Glycol (DURAN) and copolyester/ thermoplastic elastomer (CAPro), were stained using artificial saliva, cola and coffee for up to 14 days. Color stability was assessed by Vita Easyshade ADVANCE 4.0 utilizing the Commission International lightening L*a*b* color scheme.

Results: Both DURAN and CAPro aligners showed significant color changes versus baseline (p < 0.01). For DURAN, all ΔE1–ΔE1 comparisons were significant (p < 0.01) except for saliva; CAPro showed significance only in coffee (p < 0.01). Solution-based differences at both time points were highly significant for both materials (p < 0.001). Solution type had the strongest impact on color stability, followed by material and duration.

Conclusions: Color stability was significantly influenced by solution type, material, and exposure time, with the solution having the strongest effect, followed by material and time. DURAN exhibits greater resistance to staining compared to CAPro, with coffee producing the most significant discoloration, followed by cola. The degree of color change intensifies with prolonged exposure.

References

Olteanu ND, Taraboanta I, Panaite T, Balcos C, Rosu SN, Vieriu RM, et al. Color Stability of Various Orthodontic Clear Aligner Systems after Submersion in Different Staining Beverages. Materials. 2024;17(1):4009.doi:10.3390/ma17164009.

Bichu YM, Alwafi A, Liu X, Andrews J, Ludwig B, Bichu AY, et al. Advances in orthodontic clear aligner materials. Bioact Mater. 2022;22:384-403.doi:10.1016/j.bioactmat.2022.10.006.

Šimunović L, Čekalović Agović S, Marić AJ, Bačić I, Klarić E, Uribe F, et al. Color and Chemical Stability of 3D-Printed and Thermoformed Polyurethane-Based Aligners. Polymers. 2024;16(8):1067.doi:10.3390/polym16081067.

Venkatasubramanian P, Jerome MS, Ragunanthanan L, Maheshwari U, Vijayalakshmi D. Color stability of aligner materials on exposure to indigenous food products: An in-vitro study. J Dent Res Dent Clin Dent Prospects. 2022;16(4):221-8.doi:10.34172/joddd.2022.035.

Mei L, Jin C, Na A, Marra J, Guan S, Choi J. Biomechanical aging behaviour of clear aligners. Australasian Orthodontic Journal. 2024;40(1):60-6.doi:10.2478/aoj-2024-0006.

Bernard G, Rompré P, Tavares JR, Montpetit A. Colorimetric and spectrophotometric measurements of orthodontic thermoplastic aligners exposed to various staining sources and cleaning methods. Head Face Med. 2020;16(1):2.doi:10.1186/s13005-020-00218-2.

Porojan L, Vasiliu R-D, Porojan S-D, Bîrdeanu M-I. Surface Quality Evaluation of Removable Thermoplastic Dental Appliances Related to Staining Beverages and Cleaning Agents. Polymers. 2020;12(1):1736.doi:10.3390/polym12081736.

Gracco A, Mazzoli A, Favoni O, Conti C, Ferraris P, Tosi G, et al. Short-term chemical and physical changes in Invisalign appliances. Australasian Orthodontic Journal. 2009;25(1):34-40.doi:10.2478/aoj-2009-0007.

Lombardo L, Arreghini A, Maccarrone R, Bianchi A, Scalia S, Siciliani G. Optical properties of orthodontic aligners—spectrophotometry analysis of three types before and after aging. Progress in Orthodontics. 2015;16(1):41.doi:10.1186/s40510-015-0111-z.

Domingo-Jiménez T, González-Olmo MJ, Nieto-Moraleda C, Pérez-Chicharro M, Romero-Maroto M. Colourimetric changes experienced in three types of aligners according to the L’Eclairage Commission. European Journal of Orthodontics. 2024;46:cjae047.doi:10.1093/ejo/cjae047.

Šimunović L, Jurela A, Sudarević K, Bačić I, Meštrović S. Differential Stability of One-layer and Three-layer Orthodontic Aligner Blends under Thermocycling: Implications for Clinical Durability. Acta Stomatol Croat. 2023;57(4):286-99.doi:10.15644/asc57/4/1.

Zhang N, Bai Y, Ding X, Zhang Y. Preparation and characterization of thermoplastic materials for invisible orthodontics. Dental Materials Journal 2011;30(6):954-9.doi:10.4012/dmj.2011-120.

Liu C-L, Sun W-T, Liao W, Lu W-X, Li Q-W, Jeong Y, et al. Colour stabilities of three types of orthodontic clear aligners exposed to staining agents. Int J Oral Sci. 2016;8(4):246-53.doi:10.1038/ijos.2016.25.

Daniele V, Macera L, Taglieri G, Di Giambattista A, Spagnoli G, Massaria A, et al. Thermoplastic Disks Used for Commercial Orthodontic Aligners: Complete Physicochemical and Mechanical Characterization. Materials. 2020;13(1):2386.doi:10.3390/ma13102386.

Daniele V, Macera L, Taglieri G, Spera L, Marzo G, Quinzi V. Color Stability, Chemico-Physical and Optical Features of the Most Common PETG and PU Based Orthodontic Aligners for Clear Aligner Therapy. Polymers. 2022;14(1):14.doi:10.3390/polym14010014.

Staderini E, Chiusolo G, Papi M, Palone M, Lombardo L, Cordaro M. Chemical, optical, and morphological properties of TPU and PET-G samples after aging in artificial saliva: an in vitro study. BMC Oral Health. 2025;25(1):533.doi:10.1186/s12903-025-05863-0.

Cremonini F, Zabini F, Oliverio T, Bianchi A, Scalia S, Siciliani G, et al. Optical properties of seven types of clear aligners before and after in vitro aging. J Clin Orthod. 2022;56(3):149-57.

Palone M, Longo M, Arveda N, Nacucci M, Fabio D, Spedicato G, et al. General trends in aligner thickness and gap width after thermoforming procedures of six commercial clear aligners with nano-CT evaluation: an in-vitro study. The Korean Journal of Orthodontics. 2020;51(2):135-41.doi:10.4041/kjod.2021.51.2.135.

Cremonini F, Vianello M, Bianchi A, Lombardo L. A Spectrophotometry Evaluation of Clear Aligners Transparency: Comparison of 3D-Printers and Thermoforming Disks in Different Combinations. Applied Sciences. 2022;12(1):11964.doi:10.3390/ app122311964.

Goel A, Roychoudhury S, Amit K. Color stability of two different aligner materials after exposure to different liquids used in Indian diet- An in vitro comparative study. JAMDSR. 2024;12(10):38-51.doi:10.21276/jamdsr.

Ajwa N, Radhi F, Aloraini R, AlSaydalani G. Comparative color stability assessment of orthodontic clear aligners: an in vitro study. Scientific Reports. 2025;15(1):2041.doi:10.1038/s41598-025-85293-8.

Alsilani R, Sherif R, Elkhodary N. Evaluation of colour stability and surface roughness of three CAD/CAM materials (IPS e.max, Vita Enamic, and PEEK) after immersion in two beverage solutions: An in vitro study. International Journal of Applied Dental Sciences. 2022;8(1):439-49.doi:10.22271/oral.2022.v8.i1g.1460.

Gold BP, Duraisamy S, Kannan R. Comparison of Optical Properties of Clear Aligners Before and After In-vivo Aging. 2022;16(10):17-24.doi:10.7860/JCDR/2022/59186.17033.

Zafeiriadis AA, Karamouzos A, Athanasiou AE, Eliades T, Palaghias± G. In vitro spectrophotometric evaluation of Vivera® clear thermoplastic retainer discolouration. Australian Orthodontic Journal 2014; 30(2):192-200.doi:10.2478/aoj-2014-0017.

Susarchick L, Virji I, Viana G, Mahmoud M, Allareddy V, Gruber M, et al. The Effects of Staining and Cleaning on the Color and Light Transmittance Changes of a Copolyester Retainer Material with Different Surface Textures. Materials. 2022;15(1):6808.doi:10.3390/ma15196808.

Downloads

Published

2026-06-30

How to Cite

1.
Jemal HH, Hassan BA. In Vitro Color Stability Assessment of Two Clear Aligner Types. EDJ [Internet]. 2026 Jun. 30 [cited 2026 Jul. 4];9(1):39-50. Available from: https://edj.hmu.edu.krd/index.php/journal/article/view/588

Issue

Section

Original Articles