Effect of different instrument systems on the quality of bio-ceramic obturation material

(An in vitro leakage and SEM Study)

Authors

  • Dizhwar Hussein Mahmoud conservative Department (M.Sc. Student), College of Dentistry, Hawler Medical University
  • Salman R. .F Conservative Department, College of Dentistry, Hawler Medical University

DOI:

https://doi.org/10.15218/edj.2020.01

Keywords:

Bioceramic sealer,, apical leakage,, interfacial adaptation

Abstract

Background and Objectives: Bioceramic-based root canal sealers need more evidence for proving its sealing ability. The objective of this in vitro study is to measure the leakage of extracted root canals and analyze the interfacial adaptation of the bioceramic material to canal walls.

Methods: 60 extracted human lower mandibular teeth were divided randomly into 6 groups (each group 10 teeth). Group 1 and 4 were instrumented by protaper next rotary files, group 2 and 5 by wave one reciprocating files and group 3 and 6 by Two shape rotary files. All of the specimens were obturated with thermal (warm vertical compaction) technique using bioceramic as sealer. The leakage of specimens of group 1, 2 and 3 was evaluated by dye penetration method. The interfacial adaptation of specimens of group 3, 4 and 5 were analyzed using scaning electron microscopy.

Results: statistics for groups 1, 2 and 3 revealed that Wave one group showed the best leakage (mean of 0.7 mm) with significant difference. By using ANOVA; Post hoc LSD test revealed that difference between groups 1 and 3 was significant, while differences between groups 2 and 1 and between groups 2 and 3 were non-significant (p<0.05).

The descriptive statistics for groups 4, 5 and 6 revealed that Two shape file group showed the least interfacial gap width (mean­=31.2 µm). By using ANOVA; Post hoc LSD test revealed that difference between groups 4 and 5 was non-significant, while difference between groups 4 and 6 plus 5 and 6 were significant (p<0.05).

Conclusion: Different instrumentation systems had effect on the obturation quality of bioceramic material.

References

1. Chivian N. Resilon. The missing link in sealing the root canal. Compendium of continuing education in dentistry (Jamesburg, NJ: 1995). 2004;25(10A):823.
2. Kumar SA, Shivanna V, Naian MT, Shivamurthy G. Comparative evaluation of the apical sealing ability and adaptation to dentine of three resin-based sealers: An in vitro study. J Conserv Dent 2011; 14(1):16.
3.Dubok VA. Bioceramics―yesterday,today,tomorrow. Powder Metallurgy and Metal Ceramics. 2000;39(7-8):381-94.
4. Best S, Porter A, Thian E, Huang J. Bioceramics: past, present and for the future. J Eur Ceramic Soc 2008; 28(7):1319-27.
5.Brave D, Ali Nasseh A, Koch K. A review of bioceramic technology in endodontics. Roots. 2012; 4(4):6-12.
6.Ghoneim AG, Lutfy RA, Sabet NE, Fayyad DM. Resistance to fracture of roots obturated with novel canal-filling systems. J Endod 2011; 37(11):1590-2.
7. Al-Haddad A, Kasim NHA, Ab Aziz ZAC. Interfacial adaptation and thickness of bioceramic-based root canal sealers. Dental Materials Journal. 2015; 34(4):516-21.
8. Bürklein S, Hinschitza K, Dammaschke T, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J 2012;45(5):449-61.
9. Koch K, Brave D. Bioceramic technology-the game changer in endodontics. Endodontic Practice US. 2009;12:7-11.
10. Koch K, Brave D. A new endodontic obturation technique. Dentistry today 2006; 25(5):102-4.
11. Fransen JN, He J, Glickman GN, Rios A, Shulman JD, Honeyman A. Comparative assessment of ActiV GP/glass ionomer sealer, Resilon/Epiphany, and gutta-percha/AH plus obturation: a bacterial leakage study. J Endod 2008; 34(6):725-7.
12.Kokubo T. Bioceramics and their clinical applications: Elsevier; 2008.
13.Hench LL. Bioceramics: from concept to clinic. J American Ceramic Soc 1991; 74(7):1487-510.
14.Torabinejad M, Hong C, McDonald F, Ford TP. Physical and chemical properties of a new root-end filling material. J Endod 1995; 21(7):349-53.

Downloads

Published

2020-06-06

How to Cite

1.
Mahmoud DH, .F SR. Effect of different instrument systems on the quality of bio-ceramic obturation material: (An in vitro leakage and SEM Study). EDJ [Internet]. 2020 Jun. 6 [cited 2024 Dec. 21];3(1):1-9. Available from: https://edj.hmu.edu.krd/index.php/journal/article/view/edj.2020.01

Issue

Section

Original Articles