Comparison of Dimensional Accuracy of (Pmma) Denture Base Material Relined with Molloplast B Soft Liner by Different Curing Methods.

Authors

  • Radhwan H Hasan Department of Prosthodontics, College of Dentistry, Tishk international University, Erbil, Iraq.
  • Shilan H Fatah Department of Prosthodontics, College of Dentistry, Tishk international University, Erbil, Iraq.

DOI:

https://doi.org/10.15218/edj.2024.11

Keywords:

PMMA, Soft Liner, Microwave, Water Bath

Abstract

Background and objectives: The most common problem associated with the complete denture is the loss of retention after period of time therefore relining procedure is important in many cases, this study was done to compare the dimensional accuracy of PMMA before and after the application of Molloplast B Soft liner to the denture base material by different curing methods.

Methods: A total of 80 PMMA samples were used in this study, 40 (SR Triplex hot) PMMA samples polymerized in water bath, 40 (Acron MC) PMMA samples polymerized in microwave, Molloplast B soft liner (Detax, Germany) were packed between each two PMMA strip as overlap joint and cured by water bath and microwave, the dimensional accuracy of PMMA samples were measured before and after the Molloplast B soft liner application using the (DOF scan app) software device.

Results: The results showed that the dimensional accuracy of SR Triplex hot water bath polymerized PMMA samples experienced significant dimensional change after the application of Molloplast B soft liner, while in Acron MC microwave polymerized PMMA samples, non-significant dimensional changes were observed after Molloplast B soft liner application.

Conclusion: Microwave polymerized PMMA samples showed better dimensional accuracy than the water bath polymerized PMMA samples after the addition of Molloplast B Softliner.

References

Tewary S,Pawashe K (2014). Evaluation of linear dimensional accuracy of hard chairside and laboratory heat cure reline resins at different time intervals after processing. Indian J Dent Res; 25 (6): 686. DOI: 10.4103/0970-9290.152162

Polychronakis N, Yannikakis S, Zissis A (2003); A clinical 5-year longitudinal study on he dimensional changes of complete maxillary dentures. Int J Prosthodont ; 16(1): 78-81.

Parvizi A,Lindquist T,Schneider R,Williamson D, Boyer D,Dawson D (2004). Comparison of the Dimensional Accuracy of Injection‐Molded Denture Base Materials to that of Conventional Pressure‐Pack Acrylic Resin. J Prosthodont; 13 (2): 83-89. DOI: 10.1111/j.1532-849x.2004.04014.x

Abraham S, Ranganath L, Shet R, Rajesh A (2011). The Effect of Fiber Reinforcement on the Dimensional Changes of Poly Methyl Methacrylate Resin after Processing and after Immersion in Water: An in vitro Study. J Contemp Dent Pract;12 (4): 305 317. DOI: 10.5005/jp-journals-10024-1051

Kimoto S, Kobayashi N, Kobayashi K,Kawara, M (2005). Effect of bench cooling on the dimensional accuracy of heat-cured acrylic denture base material. J Dent; 33(1): 57-63. DOI: 10.1016/j.jdent.2004.08.002

Spartalis G, Cappelletti L, Schoeffel A, MicheL M, Pegoraro T, Arrais C, Neppelenbroek K ,Urban V (2015). Effect of conventional water-bath and experimental microwave polymerization cycles on the flexural properties of denture base acrylic resins. Dent. Mater ; 34 (5):623-628. DOI: 10.4012/dmj.2015-047.

Lima A, Vitti R, Amaral M, Neves A, da Silva Concilio L (2018). Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis. J Adv Prosthodont ;10(2):122. DOI: 10.4047/jap.2018.10.2.122

Shibayama R, Filho H G, Mazaro JV, Vedovatto E, Assuncao WG (2009). Effect of flasking and polymerization techniques on tooth movement in complete denture processing. J Prosthodont;18 (3): 259-264. DOI: 10.1111/j.1532-849x.2008.00421.x

Humoudi IM (2016). Dimensional stability of acrylic denture base material after poly vinyl pyrrolidone addition. TJDS; 4 (1): 29-38.

Wallace PW, Graser G N, Myers M L, Proskin HM (1991). Dimensional accuracy of denture resin cured by microwave energy . J Prosthet Dent; 66 (3):403-408. DOI: 10.1016/0022-3913(91)90271-W

Harrison A, Huggett R, Zissis A (1992). Measurements of dimensional accuracy using linear and scanning profile techniques. Int J Prosthodont;5(1).

Vallittu PK (1996). Dimensional accuracy and stability of polymethyl methacrylate reinforced with metal wire or with continuous glass fiber. J Prosthet Dent;75(6):617-621. DOI: 10.1016/s0022-3913(96)90246-2

Seo R S, Vergani CE, Pavarina A C, Compagnoni M A, Machado A L(2007). Influence of microwave disinfection on the dimensional stability of intact and relined acrylic resin denture bases. J Prosthet Dent; 98 (3): 216-223. DOI: 10.1016/s0022-3913(07)60058-4

Nirale R M, Thombre R Kubasad G (2012). Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases. J Adv Prosthodont;4 (1): 24-29.

Babu MR, Rao C, Ahmed ST ,Bharat JC, Rao N , Vinod V (2014). A comparative evaluation of the dimensional accuracy of heat polymerised PMMA denture base cured by different curing cycles and clamped by R S technique and conventional method – An In-vitro study . J Int Oral Health ; 6 (2) : 68-75 .

Wagner D A, Pipko DJ(2015). The effect of repeated microwave irradiation on the dimensional stability of a specific acrylic denture resin. J Prosthodont; 24 (1): 25-31. DOI: 10.1111/jopr.12203

Fenlon MR, Juszczyk AS, Rodriguez JM ,Curtis RV. (2010). Dimensional stability of complete denture permanent acrylic resin denture bases; A comparison of dimensions before and after a second curing cycle. Eur J Prosthodont Restor Dent;18 (1): 33-38.

Salloum A (2013). Shear bond strength of three silicone lining materials bonded to heat-cured denture resin. King Saud University J Dent Sci; 4 (1):17-20. DOI: 10.1016/j.ksujds.2012.11.003.

Gharechahi J, Asadzadeh N, Shahabian F,Gharechahi M (2014). Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique. J Dent ; 11(4): 398.

Salloum A (2014). Effect of aging on bond strength of two soft lining materials to a denture base polymer. J Indian Prosthodont Soc;14 (1): 155-160. DOI: 10.1007/s13191-014-0389-4

AI-Hanbali E, Kelleway J,Howlett J (1991). Acrylic denture distortion following double processing with microwaves or heat. J Dent; 19 (3): 176-180. DOI: 10.1016/0300-5712(91)90011-m

Machado A, Vergani C, Giampaolo E, Pavarina A (2002). Effect of a heat-treatment on the linear dimensional change of a hard chairside reline resin. J Prosthet Dent; 88 (6): 611-615. 10.1067/mpr.2002.129807

Arafa K (2016). Effect of Different Denture Base Materials and Changed Mouth Temperature on Dimensional Stability of Complete Dentures. Int J Dent;1-5. DOI: 10.1155/2016/7085063

Basso M, Giampaolo E, Vergani C, Pavarina A, Machad A, Jorge J (2015). Occlusal Pressure Analysis of Complete Dentures after Microwave Disinfection: A Clinical Study. J Prosthodont; 26 (7):606-610. DOI: 10.1111/jopr.12429.

Salim S, Sadamori S,Hamada T (1992). The dimensional accuracy of rectangular acrylic resin specimens cured by three denture base processing method. J Prosthet Dent; 67 (6):879-881. DOI: 10.1016/0022-3913(92)90606-b

Webb B C, Thomas CJ, Whittle T (2005). A 2‐year study of Candida‐associated denture stomatitis treatment in aged care subjects. Gerodontology ;22 (3): 168-176. DOI: 10.1111/j.1741-2358.2005.00065.x

EL bahra S (2015). Dimensional precision and volumetric shrinkage of PMMA denture bases polymerized with different methods. M.S.c.thesis. Christian-Albrechts university.Germany

Shankar T, Rao N, Gowd S, Ahmed S, Vinod V,Goud M (2012). A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study. J Contemp Dent Pract; 13 (6): 842-849. DOI: 10.5005/jp-journals-10024-1240.

Downloads

Published

2024-06-06

How to Cite

1.
Hasan RH, Fatah SH. Comparison of Dimensional Accuracy of (Pmma) Denture Base Material Relined with Molloplast B Soft Liner by Different Curing Methods. EDJ [Internet]. 2024 Jun. 6 [cited 2024 Jun. 30];7(1):92-100. Available from: https://edj.hmu.edu.krd/index.php/journal/article/view/275

Issue

Section

Original Articles