Evaluation Of CAD/CAM Milled Zirconia Crowns And 3D Printed Permanent Resin Crowns in the term of Adaptation

Authors

DOI:

https://doi.org/10.15218/edj.2026.9

Keywords:

Internal fit, adaptation, CAD/CAM milled zirconia crown, 3D printed permanent resin crown

Abstract

Background and Objective: This study aimed to evaluate and compare the adaptability in term of internal fitting for both types of computer aided design and computer aided milling (CAD/CAM) milled zirconia crown and 3D printed permanent resin crown in both periods of before and after thermocycling aging to evaluate the clinical performance of both types of crowns.

Method: Forty crowns were manufactured: twenty from CAD/CAM zirconia milling group and twenty from 3D-printed permanent resin group. The internal fit test is done for the crowns both before and after thermocycle aging using silicone replica technique. Measurements were taken at marginal, axial, axio-occlusal, and centro-occlusal points under stereomicroscope of 20x magnification. Data analyzed on SPSS software using multiple comparison test.

Result: There were no differences that is statistically significant in most of the points measured for both types of CAD/CAM milled zirconia and 3D-printed permanent resin crown. Thermocycling aging did not result in statistically significant differences for the internal fit of both types of crowns.

Conclusion: Clinically acceptable internal fit values were shown by both 3D-printed permanent resin crowns and CAD/CAM milled zirconia crowns. In some cases of greater adaptation, 3D-printed crowns performed similarly to milled crowns. Thermocycling had no significant impact on internal fit, indicating the materials' and fabrication techniques' long-term clinical practicality.

References

McCracken, M. S. et al. Treatment recommendations for single-unit crowns: findings from the National Dental Practice-Based Research Network. The Journal of the American Dental Association 147, 882-890 (2016). doi: 10.1016/j.adaj.2016.06.012.

Özkurt-Kayahan, Z. Monolithic zirconia: A review of the literature. Biomed Res 27, 1427-1436 (2016).

Graf, T. et al. Influence of pre-treatment and artificial aging on the retention of 3D-printed permanent composite crowns. Biomedicines 10, 2186 (2022). doi: 10.3390/biomedicines10092186

Kakinuma, H., Izumita, K., Yoda, N., Egusa, H. & Sasaki, K. Comparison of the accuracy of resin-composite crowns fabricated by three-dimensional printing and milling methods. Dental Materials Journal 41, 808-815 (2022). doi: 10.4012/dmj.2022-074

Alfaro, D. P., Ruse, N. D., Carvalho, R. M. & Wyatt, C. C. Assessment of the internal fit of lithium disilicate crowns using micro‐CT. Journal of Prosthodontics 24, 381-386 (2015). doi: 10.1111/jopr.12274

Refaie, A., Fouda, A., Bourauel, C. & Singer, L. Marginal gap and internal fit of 3D printed versus milled monolithic zirconia crowns. BMC Oral Health 23, 448 (2023). doi: 10.1186/s12903-023-03184-8

Abualsaud, R. & Alalawi, H. Fit, precision, and trueness of 3D-printed zirconia crowns compared to milled counterparts. Dentistry journal 10, 215 (2022). doi: 10.3390/dj10110215

Amalorpavam, V. et al. Stereomicroscope-Based in Vitro Study Evaluating the Marginal and Internal Fit of PEEK and PEKK Crowns. Journal of Pharmacy and Bioallied Sciences 16, S1404-S1408 (2024). doi: 10.4103/jpbs.jpbs_756_23

Doan, T. M., Nguyen, T. N., Pham, V.-K., Chotprasert, N. & Vu, C. T. B. Comparative analysis of the fit quality of monolithic zirconia veneers produced through traditional and digital workflows using silicone replica technique: an in vitro study. BMC Oral Health 24, 1566 (2024). doi: 10.1186/s12903-024-05361-9

Nizaroglu, R. T. & Küçük, C. Evaluation of marginal and internal adaptation of crowns fabricated with three different zirconia CAD/CAM materials. Nigerian Journal of Clinical Practice 27, 54-61 (2024). doi: 10.4103/njcp.njcp_410_23

Pedroche, L. O. et al. Marginal and internal fit of zirconia copings obtained using different digital scanning methods. Brazilian oral research 30, e113 (2016). doi: 10.1590/1807-3107BOR-2016.vol30.0113

Andrade, C. The P value and statistical significance: misunderstandings, explanations, challenges, and alternatives. Indian journal of psychological medicine 41, 210-215 (2019). doi: 10.4103/IJPSYM.IJPSYM_193_19

Savencu, C. E., Porojan, S. & Porojan, L. Analysis of Internal and Marginal fit of Metal-ceramic Crowns During Processing, Using Conventional and Digitized Technologies. Rev. Chim 69, 1699-1701 (2018).

Svanborg, P. A systematic review on the accuracy of zirconia crowns and fixed dental prostheses. Biomaterial investigations in dentistry 7, 9-15 (2020). doi:10.1080/26415275.2019.1708202

Tang, Z., Zhao, X., Wang, H. & Liu, B. Clinical evaluation of monolithic zirconia crowns for posterior teeth restorations. Medicine 98, e17385 (2019). doi: 10.1097/MD.0000000000017385

Teichmann, M. et al. Ten-year survival and chipping rates and clinical quality grading of zirconia-based fixed dental prostheses. Clinical oral investigations 22, 2905-2915 (2018). doi: 10.1007/s00784-018-2378-1

Khijmatgar, S. et al. Fifteen-year recall period on zirconia-based single crowns and fixed dental prostheses. A prospective observational study. BDJ open 10, 54 (2024). doi: 10.1038/s41405-024-00214-7

Shihabi, S. & Chrcanovic, B. R. Clinical outcomes of tooth-supported monolithic zirconia vs. porcelain-veneered zirconia fixed dental prosthesis, with an additional focus on the cement type: a systematic review and meta-analysis. Clinical Oral Investigations 27, 5755-5769 (2023). doi: 10.1007/s00784-023-05219-4

Balestra, D. et al. 3D Printed Materials for Permanent Restorations in Indirect Restorative and Prosthetic Dentistry: A Critical Review of the Literature. Materials, 17, 1380 (2024). doi:10.3390/ma17061380

Tribst, J. P. M., Veerman, A., Pereira, G. K. R., Kleverlaan, C. J. & Dal Piva, A. M. d. O. Comparative Strength Study of Indirect Permanent Restorations: 3D-Printed, Milled, and Conventional Dental Composites. Clinics and Practice 14, 1940-1952 (2024). doi: 10.3390/clinpract14050154

Cunali, R. S. et al. Marginal and internal adaptation of zirconia crowns: a comparative study of assessment methods. Brazilian Dental Journal 28, 467-473 (2017). doi: 10.1590/0103-6440201601531

Al-Ramadan, A., Abualsaud, R., Al-Dulaijan, Y. A., Al-Thobity, A. M. & Alalawi, H. Accuracy and Fit of Ceramic Filled 3D-Printed Resin for Permanent Crown Fabrication: An In Vitro Comparative Study. Prosthesis 6, 1029-1041 (2024). doi: 10.3390/prosthesis6050075

Marouki, C., Shamon, A. & Svanborg, P. Evaluation of fit and accuracy of single crowns fabricated from self-glazed zirconia compared with milled zirconia. The Journal of prosthetic dentistry 131, 1105-1110 (2024). doi: 10.1016/j.prosdent.2023.02.016

da Silva, S. E. G. et al. Accuracy, adaptation and margin quality of monolithic zirconia crowns fabricated by 3D printing versus subtractive manufacturing technique: a systematic review and meta-analysis of in vitro studies. Journal of Dentistry, 105089 (2024). doi: 10.1016/j.jdent.2024.105089

Mosaddad, S. A. et al. Do 3D printed and milled tooth-supported complete monolithic zirconia crowns differ in accuracy and fit? A systematic review and meta-analysis of in vitro studies. The Journal of Prosthetic Dentistry 133, 383-393 (2025). doi: 10.1016/j.prosdent.2024.04.010

Kumar, M. S., Kumar, R., Saini, R. S., Vyas, R. & Vaddamanu, S. K. A Comparative Analysis of the Accuracy of Crown Fabricated from Conventional Wax Patterns and CAD/CAM Technology–Milling and 3D Printing. Journal of Pharmacy and Bioallied Sciences 16, S3821-S3823 (2024). doi: 10.4103/jpbs.jpbs_985_24

Clark, W. A., Girnary, M., Alsahafi, T., Motamedi, A. & De Kok, I. J. Digital analysis of internal fit variation of additively manufactured crown patterns. Exploration of BioMat-X 1, 280-288 (2024). doi: 10.37349/ebmx.2024.00020

Kang, W., Kim, M.-S. & Kim, W.-G. Assessment of internal fitness on resin crown fabricated by digital light processing 3D printer. Journal of dental hygiene science 19, 238-244 (2019). doi:10.17135/jdhs.2019.19.4.238

Vasiliu, R.-D., Porojan, S. D. & Porojan, L. In vitro study of comparative evaluation of marginal and internal fit between heat-pressed and CAD-CAM monolithic glass-ceramic restorations after thermal aging. Materials 13, 4239 (2020). doi: 10.3390/ma13194239

Nassar, H. S. & Abo El-Mal, E. O. In Vitro Evaluation of The Marginal Adaptation of Monolithic Ceramic Crowns Fabricated with Different Margin Designs Using Novel CAD/CAM Material After Thermomechanical Aging. Egyptian Dental Journal 70, 575-585 (2024). doi: 10.21608/EDJ.2023.256264.2830

Sadeqi, H. A., Baig, M. R. & Al-Shammari, M. Evaluation of marginal/internal fit and fracture load of monolithic zirconia and zirconia lithium silicate (ZLS) CAD/CAM crown systems. Materials 14, 6346 (2021). doi: 10.3390/ma14216346

Downloads

Published

2026-06-30

How to Cite

1.
Kamal DJ, Ikram FS. Evaluation Of CAD/CAM Milled Zirconia Crowns And 3D Printed Permanent Resin Crowns in the term of Adaptation. EDJ [Internet]. 2026 Jun. 30 [cited 2026 Jul. 4];9(1):77-8. Available from: https://edj.hmu.edu.krd/index.php/journal/article/view/592

Issue

Section

Original Articles