Evaluation Effective Dose for Patients Undergoing Dental X-Ray Examination

Authors

  • Edrees M. Tahir Nury College of Education, Salahaddin University
  • Bayan Saber Ibrahim Basic Science Department, College of Dentistry, Hawler Medical University

DOI:

https://doi.org/10.15218/edj.2018.16

Keywords:

Intraoral radiograph, Effective dose, Maxillary molar, Mandibular molar, Male, Female, Pediatric, Adult

Abstract

Background and objectives: The dental radiographic examinations rank among the most frequent radiographic procedures. Since the radiation risks for different organs vary with age, exposure and sex. The specific objectives of this study include investigation of ESD using Thermo Luminescent Dosimeter (TLD-100) for patients undergoing dental x-ray examination.Patients and methods: ESD was measured using LiF Thermo Luminescent Dosimeters (TLD- 100) on the skin (either mandibular or maxillary arcs) for all patients. Monte Carlo simulation was performed to estimate an effective dose (ED) by using PCXMC Dose Calculation software. Analysis of data was carried out using the available statistical package of SPSS-22 (Statistical Packages for Social Sciences- version 22).

Results: The mean of the effective dose for 1-15 years old patients undergoing maxillary molar dental x-ray examination were 3.734 μSv, 3.505μSv for females and males,respectively. For 16-30 years old, the mean of the effective dose were 6.212 μSv, 3.530 μSvfor females and males, respectively. And for 31-60 years old were 3.220 μSv and 3.209 μSvfor females and males, respectively. Also for patients undergoing the mandibular molar dental x-ray examinations, the mean effective dose for 1-15 years old were 4.998 μSv, 3.969 μSv for females and males, respectively. For 16-30 years old were 3.270 μSv, 1.170 μSv forfemales and males, respectively. And for 31-60 years old were 2.020 μSv, 1.131 μSv forfemales and males, respectively.

Conclusion: The use of the entrance surface dose(ESD) or effective dose(ED) is not an accurate indicator for physicians to judge the radiation risk of an x-ray examination in accordance with the result of the present study. The overall risk from radiation in children was more than in adults and in female patients was more than in male patients. It is recommended that the average risk caused by exposure be considered as a guide to assess the risk and benefit for each age group.

References

References
1. European Commission, Radiation Protection 136, European guideline on radiation protection in dental radiology, the safe use of radiographs in dental practice, 2004. (http://europa.eu.int).
2. International Atomic Energy Agency (IAEA). Dosimetry in diagnostic radiology: an international code of practice. Technical Reports Series. Printed by the IAEA in Australia, STI/PUB/1294. 2007; 14; 5-101.
3. Gallagher A. Dowling M, Devine H, Bosmans P, Kaplanis U, Zdesar J, et al. European Survey of Dental X-ray Equipment, Radiation Protection Dosimetry. 2008; 129:284-7.
doi:10.1093/rpd/ncn037.
4. Looe HK, Pfaffenberger A, Chofor N, Eenboom F, Sering M, Rühmann A et al. Radiation exposure to children in intraoral dental radiology, Radiation Protection Dosimetry 2006;121:461-5.
doi:10.1093/rpd/ncl071.
5. Stratakis J, Damilakis J, and Gourtsoyiannis. Organ and effective dose conversion cofficients for radiographic examinations of the pediatric skull estimated by Monte Carlo methods. Eur Radial 2005; 15:1948-58.
6. Okano T, Jaideep S. Radiation dose and protection in dentistry. Jap Dent Sci Rev 2010; 46: 112-21.
doi:10.1016/j.jdsr.2009.11.004.
7. Bekas M, Krzysztof A, Pachocki. The dose received by patients during dental x-ray examination and the technical condition of radiological equipment, Med Pr 2013; 64(6):755-9.
doi.org/10.13075/mp.5893.2013.0074.
8. Gonzalez L, Vano E and Fernandez R. Reference doses in dental radio diagnostic facilities, Br J Radiol. 2001; 74: 153-6.
9. Carvalho AF, Oliveira AD, Amaral EM, Carreiro JV, Galvao JP. Dental radiation exposure in Portugal. Radiat Protect Dosimetry 1992;43(1-4):61-13.
10. Hart D, Wall BF, Hillier MC, Shrimpton PC. Frequency and collective dose for medical and dental x-ray examinations in the UK. Report HPA-CRCE-012; 2010; 78:1-58.
11. Scnaff P., Donadieu J, Pirard P, Aubert B. Population exposure to ionizing radiation from medical examination in France. Br J Radiol. 2008; 81(963):204–13.
12. International Commission on Radiological Protection. The 2007 Recommendation of the International Commission on Radiological Protection. ICRP publication 2007; 103(37):1-332.
13. Chaparian A, Dehghanzade F. Evaluation of radiation-incduced cancer risk to patients undergoing intra-oral and panoramic dental radiographies using experimental measurements and Monte Carlo calculations. Int J Radiat Res 2017; 15(2):197-205.
14. Chen TR, Tyan YS, Teng PS, Chou JH, Yeh CY,Shao CH, Tungci. Population dose from medical exposure in Taiwan for 2008. Med Physics 2011; 36(6):3139-3148.
15. Health service excutive. Population dose from Dental Radiology, 2010. Health service excutive. Available on
http;//www.hse.ie/eng/about /Who/quality

Downloads

Published

2018-12-06

How to Cite

1.
Tahir Nury EM, Ibrahim BS. Evaluation Effective Dose for Patients Undergoing Dental X-Ray Examination. EDJ [Internet]. 2018 Dec. 6 [cited 2024 Apr. 19];1(2):117-24. Available from: https://edj.hmu.edu.krd/index.php/journal/article/view/42

Issue

Section

Original Articles